Features
- It detects materials even with unstable relative permittivity and moisture percentage etc.
- Easy handling. Sensitivity can be adjusted easily.
- No sealing part and excellent resistance to pressure.
- It detects material with apparent specific gravity 0.1 or more (or 0.03 as an option).
Operating Principles
The vibration rod is operated by the vibration element built in the sensing unit. When the rod touches the material, the vibration is attenuated. This is detected electrically and outputs contact.
| Model | KVX series | XV2 series |
| Power Supply | 105/210VAC ±10% 50/60Hz | 105/210VAC ±10% 50/60Hz |
| Sensitivity | over 0.1 Specific Gravity (over 0.03 as option) | over 0.1 Specific Gravity (over 0.03 as option) |
| Output Contact | SPDT 250VAC 10A 30VDC 10A(Resistance load) | SPDT 250VAC 5A 30VDC 5A(Resistance load) |
| Temperature (Amplifier) |
-20~+60℃ (No Condensation or Freeze) |
-20~+60℃ (No Condensation or Freeze) |
| Temperature (Probe) |
-20~80℃(built-in model) (No Condensation or Freeze) |
-20~80℃(built-in model) (No Condensation or Freeze) |
| Pressure | 980kPa | 980kPa |
| Process connection | R1 | R3/4 or G3/4B |
| Enclosure Rating | IP67 | IP67 |