Features
- Safe detections from one point/multipoint control are ensured by the secured operations.
- Sewage level including viscous liquids with scum is surely detected.
- A float enables alarm or control at various applications.
Operating Principles
Float contains two weights. One weight is embedded inside the float so that the float tilts and floats in a direction and the other weight is installed in a pendular state to hold the micro switch when the micro switch and float tilt. Contact output is produced according to the tilt of the float.
| Model | KF-805N |
| Contact Capacity | AC250V 1A (Resistance Load, KARI Mini Float Switch alone) |
| Allowable Temperature | 55℃ |
| Allowable Pressure | 200KPa |
| Specific Gravity of Liquid | Over 0.8 |
| Material of Terminal Box | PVC |
| Cable Material | PVC |
| Rope Material | PP (Option 304SS) |
| Weight Material | 304SS (Option PVC) |
| Process Connection | Equivalent to JIS 10K 100A |
| Enclosure Rating | Equivalent to IP-55 |